Model Number |
SCIF Sound Group |
STC |
Weight |
Seal |
Hinge |
U/L Label |
Threshold |
| NC3-SCIF Single | 3 | Field 45 | 11.4 | NC3 | Cam Lift | A, B, C ,D, 20 Min. | Aluminum |
Generic Frame |
DWG File |
DWF File |
PDF File |
| • | SCIF models to be tested according to ASTM-E336. E90 testing will not achieve SCIF compliance. | |
| • | These doors assemblies will meet sound attenuation criteria and hardware requirements for each sound group note as outlined in JUIAF and DCID 6/9 | |
| • | SCIF definition in United States security and intelligence parlance, a Sensitive Compartmented Information Facility (SCIF; pronounced "skiff") is an enclosed area within a building that is used to process Sensitive Compartmented Information (SCI) level classified information. SCI is classified information concerning or derived from intelligence sources, methods, or analytical processes, which is required to be handled within formal access control systems established by the Director of Central Intelligence (DCI). Some entire buildings are SCIFs where all but the front foyer is secure. Access to SCIFs is limited, and all of the activity and conversation inside is presumed restricted from public disclosure. | |
| • | Specification | |
| • | Printable PDF |
| NC3-SCIF Pair | 3 | Field 45 | 11.4 | NC3 | Cam Lift | A, B, C ,D, 20 Min. | Aluminum |
Generic Frame |
DWG File |
DWF File |
PDF File |
| • | SCIF models to be tested according to ASTM-E336. E90 testing will not achieve SCIF compliance. | |
| • | SCIF definition in United States security and intelligence parlance, a Sensitive Compartmented Information Facility (SCIF; pronounced "skiff") is an enclosed area within a building that is used to process Sensitive Compartmented Information (SCI) level classified information. SCI is classified information concerning or derived from intelligence sources, methods, or analytical processes, which is required to be handled within formal access control systems established by the Director of Central Intelligence (DCI). Some entire buildings are SCIFs where all but the front foyer is secure. Access to SCIFs is limited, and all of the activity and conversation inside is presumed restricted from public disclosure. | |
| • | Specification | |
| • | Printable PDF |
| NC12-SCIF Single | 4 | Field 50 | 22.9 | NC12 | Cam Lift | N/A. | Aluminum |
Generic Frame |
DWG File |
DWF File |
PDF File |
| • | SCIF models to be tested according to ASTM-E336. E90 testing will not achieve SCIF compliance. | |
| • | These doors assemblies will meet sound attenuation criteria and hardware requirements for each sound group note as outlined in JUIAF and DCID 6/9 | |
| • | SCIF definition in United States security and intelligence parlance, a Sensitive Compartmented Information Facility (SCIF; pronounced "skiff") is an enclosed area within a building that is used to process Sensitive Compartmented Information (SCI) level classified information. SCI is classified information concerning or derived from intelligence sources, methods, or analytical processes, which is required to be handled within formal access control systems established by the Director of Central Intelligence (DCI). Some entire buildings are SCIFs where all but the front foyer is secure. Access to SCIFs is limited, and all of the activity and conversation inside is presumed restricted from public disclosure. | |
| • | Specification | |
| • | Printable PDF |
| NC12-SCIF Pair | 4 | Field 50 | 22.9 | NC12 | Cam Lift | N/A. | Aluminum |
Generic Frame |
DWG File |
DWF File |
PDF File |
| • | SCIF models to be tested according to ASTM-E336. E90 testing will not achieve SCIF compliance. | |
| • | These doors assemblies will meet sound attenuation criteria and hardware requirements for each sound group note as outlined in JUIAF and DCID 6/9 | |
| • | SCIF definition in United States security and intelligence parlance, a Sensitive Compartmented Information Facility (SCIF; pronounced "skiff") is an enclosed area within a building that is used to process Sensitive Compartmented Information (SCI) level classified information. SCI is classified information concerning or derived from intelligence sources, methods, or analytical processes, which is required to be handled within formal access control systems established by the Director of Central Intelligence (DCI). Some entire buildings are SCIFs where all but the front foyer is secure. Access to SCIFs is limited, and all of the activity and conversation inside is presumed restricted from public disclosure. | |
| • | Specification | |
| • | Printable PDF |
STC |
Model Number |
Weight |
Seal 1 |
Hinge 2 |
U/L Label 3 |
Recommended Max. V/L Area |
Hinges 2 |
Threshold |
| 44 | NC6-15-8944 | 10.2 | NC6 | C/L | BCDE | 300 SQ. IN. | STD | ALUM. OR S.S. |
Report |
100 |
125 |
160 |
200 |
250 |
315 |
400 |
500 |
630 |
800 |
1000 |
1250 |
1600 |
2000 |
2500 |
3150 |
4000 |
5000 |
TL89-246 |
29 | 38 | 38 | 40 | 43 | 42 | 42 | 44 | 48 | 48 | 48 | 44 | 40 | 42 | 45 | 47 | 49 | 52 |
Generic Frame |
DWG File |
DWF File |
PDF File |
| • | Doors tested are flush design and 1-3/4" thick. | |
| • | Specification | |
| • | Printable PDF |
| 45 | NC6-18-9345 | 12.9 | NC6 | C/L | BCDE | 300 SQ. IN. | STD | ALUM. OR S.S. |
Report |
100 |
125 |
160 |
200 |
250 |
315 |
400 |
500 |
630 |
800 |
1000 |
1250 |
1600 |
2000 |
2500 |
3150 |
4000 |
5000 |
TL93-189 |
29 | 29 | 31 | 38 | 42 | 45 | 47 | 47 | 46 | 44 | 43 | 44 | 42 | 44 | 47 | 47 | 49 | 50 |
Generic Frame |
DWG File |
DWF File |
PDF File |
| • | Doors tested are flush design and 1-3/4" thick. | |
| • | Specification | |
| • | Printable PDF |
| 46 | NC6-18-9146 | 12.9 | NC6 | C/L | BCDE | 300 SQ. IN. | STD | ALUM. OR S.S. |
Report |
100 |
125 |
160 |
200 |
250 |
315 |
400 |
500 |
630 |
800 |
1000 |
1250 |
1600 |
2000 |
2500 |
3150 |
4000 |
5000 |
TL-91-211 |
31 | 35 | 39 | 40 | 42 | 41 | 43 | 44 | 48 | 50 | 50 | 48 | 44 | 43 | 44 | 48 | 53 | 55 |
Generic Frame |
DWG File |
DWF File |
PDF File |
| • | Doors tested are flush design and 1-3/4" thick. | |
| • | Specification | |
| • | Printable PDF |
| 46 | NC7-19-9346 | 14.3 | NC7 | C/L | BCDE | 1440 SQ. IN. | STD | ALUM. OR S.S. |
Report |
100 |
125 |
160 |
200 |
250 |
315 |
400 |
500 |
630 |
800 |
1000 |
1250 |
1600 |
2000 |
2500 |
3150 |
4000 |
5000 |
TL93-191 |
24 | 32 | 36 | 37 | 39 | 38 | 37 | 41 | 45 | 48 | 49 | 51 | 53 | 54 | 53 | 53 | 55 | 56 |
Generic Frame |
DWG File |
DWF File |
PDF File |
| • | Doors tested are flush design and 1-3/4" thick. | |
| • | Specification | |
| • | Printable PDF |
| 46 | NC7-18-9346 | 12.9 | NC7 | C/L | BCDE | 300 SQ. IN. | STD | ALUM. OR S.S. |
Report |
100 |
125 |
160 |
200 |
250 |
315 |
400 |
500 |
630 |
800 |
1000 |
1250 |
1600 |
2000 |
2500 |
3150 |
4000 |
5000 |
TL93-190 |
29 | 30 | 30 | 38 | 42 | 45 | 47 | 46 | 46 | 45 | 44 | 46 | 47 | 48 | 50 | 49 | 51 | 52 |
Generic Frame |
DWG File |
DWF File |
PDF File |
| • | Doors tested are flush design and 1-3/4" thick. | |
| • | Specification | |
| • | Printable PDF |
| 46 | NC6-22-0346 | 12.7 | NC6 | C/L | N/A | N/A | STD | ALUM. OR S.S. |
Report |
100 |
125 |
160 |
200 |
250 |
315 |
400 |
500 |
630 |
800 |
1000 |
1250 |
1600 |
2000 |
2500 |
3150 |
4000 |
5000 |
TL03-434 |
35 | 39 | 41 | 40 | 42 | 45 | 45 | 46 | 45 | 41 | 42 | 43 | 47 | 49 | 50 | 49 | 49 | 51 |
Generic Frame |
DWG File |
DWF File |
PDF File |
| • | Doors tested are flush design and 2 1/4" thick. | |
| • | Specification | |
| • | Printable PDF |
| 50 | NC7-15-8950 | 10.2 | NC7 | C/L | BCDE | CALL | STD | ALUM. OR S.S. |
Report |
100 |
125 |
160 |
200 |
250 |
315 |
400 |
500 |
630 |
800 |
1000 |
1250 |
1600 |
2000 |
2500 |
3150 |
4000 |
5000 |
TL89-247 |
30 | 37 | 38 | 39 | 40 | 42 | 43 | 45 | 48 | 49 | 51 | 53 | 53 | 53 | 54 | 55 | 56 | 58 |
Generic Frame |
DWG File |
DWF File |
PDF File |
| • | Doors tested are flush design and 1-3/4" thick. | |
| • | Specification | |
| • | Printable PDF |
| 50 | NC7-18-9150 | 12.9 | NC7 | C/L | ABCDE | CALL | STD | ALUM. OR S.S. |
Report |
100 |
125 |
160 |
200 |
250 |
315 |
400 |
500 |
630 |
800 |
1000 |
1250 |
1600 |
2000 |
2500 |
3150 |
4000 |
5000 |
TL91-210 |
32 | 36 | 39 | 41 | 42 | 41 | 43 | 44 | 49 | 50 | 51 | 52 | 53 | 54 | 55 | 55 | 56 | 57 |
Generic Frame |
DWG File |
DWF File |
PDF File |
| • | Doors tested are flush design and 1-3/4" thick. | |
| • | Specification | |
| • | Printable PDF |
| 51 | NC7-17-8951 | 14.4 | NC7 | C/L | ABCDE | CALL | STD | ALUM. OR S.S. |
Report |
100 |
125 |
160 |
200 |
250 |
315 |
400 |
500 |
630 |
800 |
1000 |
1250 |
1600 |
2000 |
2500 |
3150 |
4000 |
5000 |
TL89-241 |
34 | 43 | 39 | 40 | 45 | 46 | 46 | 46 | 48 | 50 | 51 | 52 | 53 | 55 | 58 | 58 | 57 | 58 |
Generic Frame |
DWG File |
DWF File |
PDF File |
| • | Doors tested are flush design and 1-3/4" thick. | |
| • | Specification | |
| • | Printable PDF |
STC |
Model Number |
Weight |
Seal 1 |
Hinge 2 |
U/L Label 3 |
Recommended Max. V/L Area |
Hinges 2 |
Threshold |
| 40 | NC5-15-0340 | 8.5 | NC5 | STD | BCDE | 300 SQ. IN. | C/L | ALUM. OR S.S. |
Report |
100 |
125 |
160 |
200 |
250 |
315 |
400 |
500 |
630 |
800 |
1000 |
1250 |
1600 |
2000 |
2500 |
3150 |
4000 |
5000 |
TL03-440 |
21 | 26 | 33 | 36 | 36 | 37 | 38 | 40 | 41 | 42 | 41 | 41 | 42 | 41 | 40 | 38 | 38 | 40 |
Generic Frame |
DWG File |
DWF File |
PDF File |
| • | Doors tested are flush design and 1-3/4" thick. | |
| • | Specification | |
| • | Printable PDF |
| 44 | NC3-15A-0344 | 8.5 | NC3 | STD | BCDE | 300 SQ. IN. | C/L | ALUM. OR S.S. |
Report |
100 |
125 |
160 |
200 |
250 |
315 |
400 |
500 |
630 |
800 |
1000 |
1250 |
1600 |
2000 |
2500 |
3150 |
4000 |
5000 |
TL03-438 |
21 | 26 | 32 | 37 | 38 | 40 | 43 | 45 | 45 | 45 | 42 | 41 | 43 | 46 | 47 | 47 | 45 | 43 |
Generic Frame |
DWG File |
DWF File |
PDF File |
| • | Doors tested are flush design and 1-3/4" thick. | |
| • | Specification | |
| • | Printable PDF |
| 44 | NC5-19-0344 | 14.3 | NC5 | C/L | BCDE | 1440 SQ. IN. | STD | ALUM. OR S.S. |
Report |
100 |
125 |
160 |
200 |
250 |
315 |
400 |
500 |
630 |
800 |
1000 |
1250 |
1600 |
2000 |
2500 |
3150 |
4000 |
5000 |
TL03-430 |
34 | 28 | 28 | 32 | 39 | 44 | 44 | 43 | 42 | 41 | 41 | 43 | 45 | 47 | 50 | 51 | 52 | 52 |
Generic Frame |
DWG File |
DWF File |
PDF File |
| • | Doors tested are flush design and 1-3/4" thick. | |
| • | Specification | |
| • | Printable PDF |
| 45 | NC5-15A-0345 | 8.5 | NC5 | STD | BCDE | 300 SQ. IN. | C/L | ALUM. OR S.S. |
Report |
100 |
125 |
160 |
200 |
250 |
315 |
400 |
500 |
630 |
800 |
1000 |
1250 |
1600 |
2000 |
2500 |
3150 |
4000 |
5000 |
TL03-439 |
22 | 26 | 33 | 38 | 38 | 41 | 43 | 45 | 46 | 46 | 45 | 44 | 46 | 47 | 48 | 47 | 46 | 47 |
Generic Frame |
DWG File |
DWF File |
PDF File |
| • | Doors tested are flush design and 1-3/4" thick. | |
| • | Specification | |
| • | Printable PDF |
| 46 | NC5-19FG-9346 | 14.3 | NC5 | C/L | BCDE | 1725 SQ. IN. | STD | ALUM. OR S.S. |
Report |
100 |
125 |
160 |
200 |
250 |
315 |
400 |
500 |
630 |
800 |
1000 |
1250 |
1600 |
2000 |
2500 |
3150 |
4000 |
5000 |
TL93-192 |
24 | 31 | 36 | 37 | 40 | 38 | 37 | 40 | 44 | 47 | 49 | 52 | 54 | 55 | 54 | 54 | 56 | 56 |
Generic Frame |
DWG File |
DWF File |
PDF File |
| • | Doors tested are flush design and 1-3/4" thick. | |
| • | Specification | |
| • | Printable PDF |
| 49 | NC5-18-9149 | 12.9 | NC5 | C/L | ABCDE | CALL | STD | ALUM. OR S.S. |
Report |
100 |
125 |
160 |
200 |
250 |
315 |
400 |
500 |
630 |
800 |
1000 |
1250 |
1600 |
2000 |
2500 |
3150 |
4000 |
5000 |
TL91-208 |
32 | 35 | 39 | 41 | 41 | 40 | 43 | 45 | 49 | 50 | 50 | 51 | 52 | 53 | 53 | 49 | 51 | 53 |
Generic Frame |
DWG File |
DWF File |
PDF File |
| • | Doors tested are flush design and 1-3/4" thick. | |
| • | Specification | |
| • | Printable PDF |
| 49 | NC3-22-0349 | 12.7 | NC3 | C/L | NA | NA | STD | ALUM. OR S.S. |
Report |
100 |
125 |
160 |
200 |
250 |
315 |
400 |
500 |
630 |
800 |
1000 |
1250 |
1600 |
2000 |
2500 |
3150 |
4000 |
5000 |
TL03-437 |
35 | 39 | 41 | 40 | 43 | 45 | 44 | 47 | 48 | 48 | 48 | 49 | 50 | 50 | 50 | 52 | 54 | 55 |
Generic Frame |
DWG File |
DWF File |
PDF File |
| • | Doors tested are flush design and 2 1/4" thick. | |
| • | Specification | |
| • | Printable PDF |
| 51 | NC3-17-8951 | 14.4 | NC3 | C/L | ABCDE | CALL | STD | ALUM. OR S.S. |
Report |
100 |
125 |
160 |
200 |
250 |
315 |
400 |
500 |
630 |
800 |
1000 |
1250 |
1600 |
2000 |
2500 |
3150 |
4000 |
5000 |
TL89-243 |
36 | 47 | 39 | 40 | 45 | 46 | 45 | 47 | 49 | 50 | 51 | 53 | 53 | 54 | 55 | 57 | 56 | 57 |
Generic Frame |
DWG File |
DWF File |
PDF File |
| • | Doors tested are flush design and 1-3/4" thick. | |
| • | Specification | |
| • | Printable PDF |
| 52 | NC5-19-9352 | 12.4 | NC5 | C/L | ABCDE | CALL | NA | ALUM. OR S.S. |
Report |
100 |
125 |
160 |
200 |
250 |
315 |
400 |
500 |
630 |
800 |
1000 |
1250 |
1600 |
2000 |
2500 |
3150 |
4000 |
5000 |
TL93-195 |
31 | 34 | 42 | 48 | 44 | 46 | 49 | 48 | 51 | 51 | 52 | 53 | 53 | 55 | 54 | 55 | 55 | 56 |
Generic Frame |
DWG File |
DWF File |
PDF File |
| • | Doors tested are flush design and 1-3/4" thick. | |
| • | Specification | |
| • | Printable PDF |
| 53 | NC5-19-9353 | 12.4 | NC5 | C/L | ABCDE | CALL | NA | ALUM. OR S.S. |
Report |
100 |
125 |
160 |
200 |
250 |
315 |
400 |
500 |
630 |
800 |
1000 |
1250 |
1600 |
2000 |
2500 |
3150 |
4000 |
5000 |
TL93-193 |
32 | 34 | 43 | 49 | 45 | 49 | 50 | 49 | 53 | 53 | 55 | 54 | 54 | 55 | 55 | 55 | 57 | 58 |
Generic Frame |
DWG File |
DWF File |
PDF File |
| • | Doors tested are flush design and 1-3/4" thick. | |
| • | Specification | |
| • | Printable PDF |
| 55 | NC12-30-9155 | 22.7 | NC12 | C/L | NA | NA | NA | ALUM. OR S.S. |
Report |
100 |
125 |
160 |
200 |
250 |
315 |
400 |
500 |
630 |
800 |
1000 |
1250 |
1600 |
2000 |
2500 |
3150 |
4000 |
5000 |
TL91-200 |
39 | 39 | 42 | 43 | 45 | 46 | 50 | 50 | 52 | 54 | 56 | 56 | 59 | 60 | 62 | 63 | 64 | 64 |
Generic Frame |
DWG File |
DWF File |
PDF File |
| • | Doors tested are flush design and 3" thick. | |
| • | Specification | |
| • | Printable PDF |
STC |
Model Number |
Weight |
Seal 1 |
Hinge 2 |
U/L Label 3 |
Recommended Max. V/L Area |
Hinges 2 |
Threshold |
| 46 | NC3-WD1-9146 | 7.0 | NC3 | C/L | C | CALL | NA | ALUM. OR S.S. |
Report |
100 |
125 |
160 |
200 |
250 |
315 |
400 |
500 |
630 |
800 |
1000 |
1250 |
1600 |
2000 |
2500 |
3150 |
4000 |
5000 |
TL91-206 |
27 | 24 | 30 | 35 | 37 | 38 | 43 | 45 | 46 | 47 | 46 | 47 | 50 | 51 | 52 | 52 | 52 | 52 |
Generic Frame |
DWG File |
DWF File |
PDF File |
| • | Doors tested are flush design and 1-3/4" thick. | |
| • | Specification | |
| • | Printable PDF |
| 47 | NC5-WD1-9147 | 7.0 | NC5 | C/L | C | CALL | NA | ALUM. OR S.S. |
Report |
100 |
125 |
160 |
200 |
250 |
315 |
400 |
500 |
630 |
800 |
1000 |
1250 |
1600 |
2000 |
2500 |
3150 |
4000 |
5000 |
TL91-207 |
27 | 24 | 31 | 35 | 37 | 38 | 43 | 45 | 47 | 48 | 49 | 50 | 50 | 51 | 53 | 54 | 54 | 55 |
Generic Frame |
DWG File |
DWF File |
PDF File |
| • | Doors tested are flush design and 1-3/4" thick. | |
| • | Specification | |
| • | Printable PDF |
| 49 | NC3-WD2-9149 | 11.0 | NC3 | C/L | C | CALL | NA | ALUM. OR S.S. |
Report |
100 |
125 |
160 |
200 |
250 |
315 |
400 |
500 |
630 |
800 |
1000 |
1250 |
1600 |
2000 |
2500 |
3150 |
4000 |
5000 |
TL91-208 |
32 | 35 | 39 | 41 | 41 | 40 | 43 | 45 | 49 | 50 | 50 | 51 | 52 | 53 | 53 | 49 | 51 | 53 |
Generic Frame |
DWG File |
DWF File |
PDF File |
| • | Doors tested are flush design and 1-3/4" thick. | |
| • | Specification | |
| • | Printable PDF |
| 50 | NC3-WD2-8550 | 11.0 | NC3 | C/L | C | CALL | NA | ALUM. OR S.S. |
Report |
100 |
125 |
160 |
200 |
250 |
315 |
400 |
500 |
630 |
800 |
1000 |
1250 |
1600 |
2000 |
2500 |
3150 |
4000 |
5000 |
TL85-327 |
27 | 29 | 36 | 39 | 42 | 45 | 46 | 50 | 49 | 49 | 49 | 50 | 50 | 54 | 56 | 56 | 55 | 55 |
Generic Frame |
DWG File |
DWF File |
PDF File |
| • | Doors tested are flush design and 1-3/4" thick. | |
| • | Specification | |
| • | Printable PDF |
| 53 | NC5-WD3-9353 | 12.5 | NC5 | C/L | C | CALL | NA | ALUM. OR S.S. |
Report |
100 |
125 |
160 |
200 |
250 |
315 |
400 |
500 |
630 |
800 |
1000 |
1250 |
1600 |
2000 |
2500 |
3150 |
4000 |
5000 |
TL93-193 |
32 | 34 | 43 | 49 | 45 | 49 | 50 | 49 | 53 | 53 | 55 | 54 | 54 | 55 | 55 | 55 | 57 | 58 |
Generic Frame |
DWG File |
DWF File |
PDF File |
| • | Doors tested are flush design and 1-3/4" thick. | |
| • | Specification | |
| • | Printable PDF |
STC |
Model Number |
Weight |
Seal 1 |
Hinge 2 |
U/L Label 3 |
Recommended Max. V/L Area |
Hinges 2 |
Threshold |
| 45 | NC6-216-8945 | 14.4 | NC6/A1 | C/L | BCDE | 300 SQ. IN. | STD | ALUM. OR S.S. |
Report |
100 |
125 |
160 |
200 |
250 |
315 |
400 |
500 |
630 |
800 |
1000 |
1250 |
1600 |
2000 |
2500 |
3150 |
4000 |
5000 |
TL89-228 |
35 | 40 | 37 | 40 | 45 | 45 | 46 | 46 | 47 | 48 | 47 | 46 | 43 | 41 | 43 | 47 | 49 | 49 |
Generic Frame |
DWG File |
DWF File |
PDF File |
| • | Doors tested are flush design and 1-3/4" thick. | |
| • | Specification | |
| • | Printable PDF |
| 46 | NC3-216-8946 | 14.4 | NC3/A1 | C/L | BCDE | 300 SQ. IN. | STD | ALUM. OR S.S. |
Report |
100 |
125 |
160 |
200 |
250 |
315 |
400 |
500 |
630 |
800 |
1000 |
1250 |
1600 |
2000 |
2500 |
3150 |
4000 |
5000 |
TL89-239 |
35 | 42 | 36 | 40 | 45 | 44 | 45 | 45 | 46 | 45 | 44 | 44 | 44 | 45 | 47 | 49 | 50 | 50 |
Generic Frame |
DWG File |
DWF File |
PDF File |
| • | Doors tested are flush design and 1-3/4" thick. | |
| • | Specification | |
| • | Printable PDF |
| 47 | NC6-216-8947 | 14.4 | NC6/A1 | C/L | BCDE | 216 SQ. IN. | STD | ALUM. OR S.S. |
Report |
100 |
125 |
160 |
200 |
250 |
315 |
400 |
500 |
630 |
800 |
1000 |
1250 |
1600 |
2000 |
2500 |
3150 |
4000 |
5000 |
TL89-235 |
34 | 32 | 38 | 42 | 49 | 46 | 48 | 47 | 48 | 49 | 48 | 45 | 45 | 44 | 46 | 49 | 50 | 51 |
Generic Frame |
DWG File |
DWF File |
PDF File |
| • | Doors tested are flush design and 1-3/4" thick. | |
| • | Specification | |
| • | Printable PDF |
| 49 | NC6-216-8949 | 14.4 | NC6/A2 | C/L | ABCDE | CALL | NA | ALUM. OR S.S. |
Report |
100 |
125 |
160 |
200 |
250 |
315 |
400 |
500 |
630 |
800 |
1000 |
1250 |
1600 |
2000 |
2500 |
3150 |
4000 |
5000 |
TL89-236 |
34 | 37 | 36 | 40 | 45 | 45 | 48 | 47 | 48 | 49 | 49 | 51 | 50 | 46 | 48 | 50 | 51 | 52 |
Generic Frame |
DWG File |
DWF File |
PDF File |
| • | Doors tested are flush design and 1-3/4" thick. | |
| • | Specification | |
| • | Printable PDF |
| 51 | NC7-216-8951 | 14.4 | NC7/A2 | C/L | ABCDE | CALL | NA | ALUM. OR S.S. |
Report |
100 |
125 |
160 |
200 |
250 |
315 |
400 |
500 |
630 |
800 |
1000 |
1250 |
1600 |
2000 |
2500 |
3150 |
4000 |
5000 |
TL89-232 |
36 | 40 | 36 | 40 | 45 | 44 | 47 | 47 | 48 | 49 | 50 | 51 | 53 | 54 | 57 | 58 | 57 | 56 |
Generic Frame |
DWG File |
DWF File |
PDF File |
| • | Doors tested are flush design and 1-3/4" thick. | |
| • | Specification | |
| • | Printable PDF |
STC |
Model Number |
Weight |
Seal 1 |
Hinge 2 |
U/L Label 3 |
Recommended Max. V/L Area |
Hinges 2 |
Threshold |
| 40 | NC6-225SL-9840 | 15.5 | NC6 | NA | NA | NA | NA | ALUM. OR S.S. |
Report |
100 |
125 |
160 |
200 |
250 |
315 |
400 |
500 |
630 |
800 |
1000 |
1250 |
1600 |
2000 |
2500 |
3150 |
4000 |
5000 |
TL98-426 |
29 | 33 | 37 | 42 | 41 | 41 | 40 | 39 | 36 | 36 | 37 | 36 | 38 | 41 | 44 | 43 | 46 | 46 |
Generic Frame |
DWG File |
DWF File |
PDF File |
| • | Sliding Man Door includes a manual or power operated track and trolley system. | |
| • | Specification | |
| • | Printable PDF |
STC |
Model Number |
Thickness |
Weight |
Area Tested |
Glass Type |
Glazing Type |
| 47 | NCV-2525MW-47 | 8" | 10.5 | 21 SQ. FT. | 1/4" MONO x 1/4" WIRE | NEOPRENE |
Report |
100 |
125 |
160 |
200 |
250 |
315 |
400 |
500 |
630 |
800 |
1000 |
1250 |
1600 |
2000 |
2500 |
3150 |
4000 |
5000 |
TL88-109 |
30 | 36 | 30 | 34 | 40 | 42 | 41 | 47 | 50 | 50 | 46 | 52 | 52 | 45 | 46 | 53 | 54 | 60 |
Generic Frame |
DWG File |
DWF File |
PDF File |
| • | Specification | |
| • | Printable PDF |
| 49 | NCV-2525L-49 | 8" | 11.0 | 21 SQ. FT. | 1/4" LAM x 1/4" LAM | NEOPRENE |
Report |
100 |
125 |
160 |
200 |
250 |
315 |
400 |
500 |
630 |
800 |
1000 |
1250 |
1600 |
2000 |
2500 |
3150 |
4000 |
5000 |
TL88-107 |
22 | 38 | 33 | 34 | 41 | 42 | 41 | 47 | 50 | 50 | 46 | 52 | 52 | 55 | 54 | 57 | 59 | 63 |
Generic Frame |
DWG File |
DWF File |
PDF File |
| • | Specification | |
| • | Printable PDF |
| 50 | NCV-3825L-50 | 8" | 12.4 | 21 SQ. FT. | 1/4" LAM x 3/8" LAM | NEOPRENE |
Report |
100 |
125 |
160 |
200 |
250 |
315 |
400 |
500 |
630 |
800 |
1000 |
1250 |
1600 |
2000 |
2500 |
3150 |
4000 |
5000 |
TL88-106 |
29 | 37 | 35 | 37 | 42 | 43 | 42 | 48 | 50 | 50 | 46 | 52 | 52 | 56 | 55 | 58 | 60 | 64 |
Generic Frame |
DWG File |
DWF File |
PDF File |
| • | Specification | |
| • | Printable PDF |
| 52 | NCV-2525-9852 | 9 5/8" | 14.0 | 21 SQ. FT. | 1/4" LAM x 1/4" LAM | NEOPRENE |
Report |
100 |
125 |
160 |
200 |
250 |
315 |
400 |
500 |
630 |
800 |
1000 |
1250 |
1600 |
2000 |
2500 |
3150 |
4000 |
5000 |
TL98-423 |
30 | 30 | 38 | 39 | 41 | 43 | 44 | 49 | 53 | 54 | 57 | 60 | 61 | 61 | 61 | 63 | 64 | 62 |
Generic Frame |
DWG File |
DWF File |
PDF File |
| • | Specification | |
| • | Printable PDF |
| 53 | NCV-2537-9853 | 9 5/8" | 15.5 | 21 SQ. FT. | 1/4" LAM x 3/8" LAM | NEOPRENE |
Report |
100 |
125 |
160 |
200 |
250 |
315 |
400 |
500 |
630 |
800 |
1000 |
1250 |
1600 |
2000 |
2500 |
3150 |
4000 |
5000 |
TL98-422 |
29 | 34 | 38 | 40 | 42 | 44 | 45 | 52 | 54 | 54 | 57 | 59 | 60 | 61 | 62 | 63 | 64 | 63 |
Generic Frame |
DWG File |
DWF File |
PDF File |
| • | Specification | |
| • | Printable PDF |
| 56 | NCV-3775-9856 | 9 5/8" | 21.5 | 21 SQ. FT. | 3/8" LAM x 3/4" LAM | NEOPRENE |
Report |
100 |
125 |
160 |
200 |
250 |
315 |
400 |
500 |
630 |
800 |
1000 |
1250 |
1600 |
2000 |
2500 |
3150 |
4000 |
5000 |
TL98-421 |
31 | 37 | 40 | 42 | 46 | 51 | 52 | 54 | 55 | 54 | 57 | 61 | 63 | 64 | 64 | 65 | 64 | 63 |
Generic Frame |
DWG File |
DWF File |
PDF File |
| • | Specification | |
| • | Printable PDF |